Chapter 2 Installing the SN 5428 Storage Router

Installing the SN 5428 Chassis

Rack-Mounting the SN 5428 Storage Router

You can rack-mount the SN 5428 Storage Router chassis in a 19-inch equipment rack with the front panel forward.

The accessory kit that is shipped with your storage router contains two L-brackets, six L-bracket screws, a cable guide (with mounting screw), and two sets of rack-post screws. One set of rack-post screws consists of four 10-32 3/4” screws; the other set consists of four 12-24 3/4” screws.

Note If your mounting-post holes cannot accommodate the rack-post screws shipped with your storage router, you will need to supply other screws (and clips if necessary) suitable for your equipment rack.

You need the following tools to install the storage router in a rack:

Phillips screwdriver suitable for L-bracket screws and cable-guide screw

Phillips screwdriver suitable for the rack-post screws

Tape measure

To install the storage router in a rack, follow these steps:

Step 1 Prepare for installation as follows:

a.Place the storage router on the floor or on a sturdy table as close as possible to the rack. Leave enough clearance so that you can move around the storage router.

b.Use a tape measure to measure the depth of the rack. Measure from the outside of the front mounting posts to the outside of the rear mounting strip. The depth must be at least 19 inches (48.26 cm) but not more than 32 inches (81.3 cm).

c.Measure the space between the inner edges of the left-front and right-front mounting posts to ensure that the space is 17.75 inches (45.72 cm) wide.

Step 2 Remove the front screw from each side of the chassis. (See Figure 2-1.) You may discard the screws.

 

 

Cisco SN 5428 Storage Router Hardware Installation Guide

 

 

 

 

 

 

OL-4796-01

 

 

2-7

 

 

 

Page 33
Image 33
Cisco Systems manual Rack-Mounting the SN 5428 Storage Router