7-10
Software Configuration Guide—Release 12.2(25)SG
OL-7659-03
Chapter7 Environmental Monitoring and Power Management
Power Management
The following example shows how to display the current power redundancy mode. The power supplies
needed by system: 2 indicates that the switch is in combined mode.
Switch# show power supplies
Power supplies needed by system:2
Switch#
Insufficient Inline Power Handling for Supervisor Engine II-TS
When the Supervisor Engine II+TS is used with the 1400 W DC power supply (PWR-C45-1400DC), and
only one 12.5 A input of the power supply is used, the supervisor engine’s power consumption may vary
depending on the type of linecard used and on whether a linecard is inserte d at slots 2 and 3. The power
consumption varies between 155 W and 330 W, which also affects the maximum amount of available
inline power through the supervisor engine (0 W to 175 W). Con sequently, it is possible for the
supervisor engine to deny inline power to a connected inline power device when one or more linecards
are inserted into the chassis.
The output of the show power detail and show power module commands reveals the variable amount
of power consumption attributable to the supervisor engine and summarizes the supervisor engine’s
inline power.
Switch# show power detail
show power detail
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-1400DC DCSP1400W good good n.a.
PS1-1 12.5A good
PS1-2 15.0A off
PS1-3 15.0A off
PS2 none -- -- -- --
Power supplies needed by system : 1
Power supplies currently available : 1
Power Summary Maximum
(in Watts) Used Available
---------------------- ---- ---------
System Power (12V) 360 360
Inline Power (-50V) 0 0
Backplane Power (3.3V) 0 40
---------------------- ---- ---------
Total 360 400
Module Inline Power Summary (Watts)
(12V -> -48V on board conversion)
---------------------------------
Maximum
Mod Used Available
--- ---- ---------
1 5 25
--- ---- ---------