ESC "c" "4" n

[Function]

Selecting the paper near end sensor valid for print stop

 

 

 

[Code]

<1B>H<63>H<34>H n

 

 

 

 

[Range]

0 n 255

 

 

 

 

 

 

[Outline]

This command selects the no-paper detector state in which printing should be stopped.

 

 

 

 

 

 

 

 

 

 

 

 

Bit

 

Function

 

 

Value

 

 

 

 

 

0

 

1

 

 

 

 

 

 

 

 

 

 

 

0

 

Paper near end

 

Disabled

 

Enabled

 

 

 

1

 

Undefined

 

 

 

 

 

2

 

Undefined

 

 

 

 

 

3

 

Undefined

 

 

 

 

 

4

 

Undefined

 

 

 

 

 

5

 

Undefined

 

 

 

 

 

6

 

Undefined

 

 

 

 

 

7

 

Undefined

 

 

 

[Default]

n = 0

 

 

 

 

 

 

ESC "c" "5" n

 

 

 

 

 

 

 

 

 

[Function]

Selecting the panel switch enable/disable

 

 

 

 

[Code]

<1B>H <63>H <35>H n

 

 

 

 

[Range]

0 n 255

 

 

 

 

 

 

[Outline]

This command enables/disables the panel switches. n is valid only for the least significant

 

bit.

 

 

 

 

 

 

 

 

Setting n = 1 disables the panel switches.

 

 

 

 

 

 

Setting n = 0 enables the panel switches.

 

 

 

 

[Caution]

If the panel switches are disabled with this command, the LF switch will be disabled.

 

Therefore, the paper cannot be fed by the LF switch.

 

 

 

[Default]

n = 0

 

 

 

 

 

 

ESC "d" n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Function]

Printing and n-line paper feed

 

 

 

 

[Code]

<1B>H <64>H n

 

 

 

 

 

 

[Range]

0 n 255

 

 

 

 

 

 

[Outline]

This command feeds the paper by n-lines after printing the one line worth of data saved in the

 

print buffer.

 

 

 

 

 

 

Page 112
Image 112
Citizen Systems iDP-3550, iDP-3551 user manual ESC c 4 n, ESC c 5 n, ESC d n