11. DRAWER KICK-OUT CONNECTOR

11.1Specifications of Drawer Kick-Out Connector

(1)Drawer kick-out drive signal

Parallel

----- Can be learned at the no. 34 pin of the interface connector

Serial

----- Provided with a command to learn the status in the STAR and ESC/POS modes.

(2)Electrical characteristics

1)Drive voltage: 24 V DC

2)Drive current: 0.8 A at maximum (Within 510 ms)

3) Switch signal: Signal level

"L"

= 0 to 0.5 V

 

"H"

= 3 to 5 V

11.2Connector's Pin Configuration

No.

Signal

Function

 

1

FG

Frame Ground

 

2

DRAWER 1

Drawer 1 drive signal

 

3

DRSW

Drawer switch input

 

4

VDR

Drawer drive power

 

5

DRAWER 2

Drawer 2 drive signal

 

6

GND

Common ground on the circuit

 

Connector used

: TM5RJ3-66 (HIROSE)

Applicable connector

: TM3P-66P (HIROSE) or equivalent

CAUTION : •

No output is made while printing.

The drawers 1 and 2 cannot be driven simultaneously.

A solenoid used for the drawer should be of 36Ω or more. An output current should be kept below 0.8 A. Use beyond this limit cannot be assured.

This connector cannot be connected to a telephone line. Do not connect other than the solenoid.

11.3Drive Circuit