9.3.3Timing Chart

(1)Data input and printing timing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1, T2, T3

: 0.5 μs MIN

 

 

 

 

 

 

T4

: 270 ns MAX

 

 

 

 

 

 

T5

: 2.3μs TYP

 

 

 

 

 

 

T6

: 500 ms MIN (At power-on)

9.3.4Data Receiving Control

When the BUSY signal is at "LOW," the printer can receive the data from the host, but when at "HIGH," it cannot.