VT

[Function]

Vertical tab

[Code]

<0B> H

[Outline]

This command feeds the paper to the next vertical tab position. It cannot be fed unless the

 

vertical tab position has been set. If the current position is equal to or greater than the

 

maximum set vertical tab position, it will be fed to the head of the next page.

ESC "B" [n]k NUL

[Function]

Setting the vertical tab position

[Code]

<1B>H <42>H [n]k <00>H

[Range]

1

n 255

 

1

k 16

[Outline]

This command cancels the already set vertical tab positions and sets new vertical tab

 

positions. They are set in the ascending order and ends with <00>. Up to 16 vertical tabs

 

can be set. If the tab setting position <nk> is equal or smaller than the preceding set position

 

<nk-1>, it is assumed that setting of the vertical tabs has been completed.

Page 80
Image 80
Citizen Systems iDP-3550, iDP-3551 user manual ESC B nk NUL