Appendices ~ Appendix E: Serial Commands

FLOW

This command selects or reports whether hardware flow control is enable or disabled for the AP400. Hardware flow control is implemented using RTS and CTS.

[DEVICE] FLOW <X>

Explanation

<X>

X=0

Sets flow control to OFF

X=1

Sets flow control to ON

X=Null

Parameter to return the current mode

Return Values

The command will return the updated condition (On=1, Off=0) of the AP400 in the same format as the command.

FMP

This command selects or returns the current status of the first microphone priority mode for the AP400.

[DEVICE] FMP <X>

Explanation

<X>

X=0

Parameter to select first microphone priority

 

mode to OFF

X=1

Parameter to select first microphone priority

 

mode to ON

X=Null

Parameter to return the current mode

Return Values

The command will return the updated condition (On=1, Off=0) of first mic priority mode in the same format as the command.

51

FPP

This command sets and reports the current passcode setting for the AP400.

[DEVICE] FPP <XXXXX>

Explanation

<XXXXX>

X=1

▲ button

X=2

Enter button

X=3

Esc button

X=4

▼ button

X=5

Meter button

X=6

Input button

X=7

System button

X=8

Output button

X=9

Routing button

X=Null

Parameter to return current passcode

Return Values

The command returns the current or updated condition of the front panel passcode.