Installation ~ Networking Units
A G-Link network supports ✍ connection of a maximum of any combination of 8 AP400s and AP800s. It also supports up to 16 additional AP10s, for a maximum of 24 telephone
lines.
G-Link connections
Using the G-Link connectors, you can connect up to eight AP800/400s and 16 AP10 units, where the total number of microphone inputs does not exceed 64. Make connections between units in daisy-chain fashion using the short RJ-45 jumper (provided). If your units are further apart (maximum distance 20 feet), use category- five twisted-pair cable (10 BaseT).
For a single-unit system, no connection is required in either G-Link In or G-Link Out connectors.
Figure 2.4. G-Link Network Connections
To create a G-Link network
1.Insert a G-Link terminator (provided) in the G-Link In connector of the first unit in the network.
2.Connect the RJ-45 jumper cable (or Cat. 5 twisted-pair cable) to the G-Link Out connector of the first unit and to the G-Link In connector of the second unit. Continue connecting units in the same fashion.
3.Plug the G-Link terminator in the G-Link Out connector on the last unit to complete the network connections.
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760