Appendices ~ Appendix E: Serial Commands

PP

This command changes or reports back the state of the phantom power for a microphone.

[DEVICE] PP <CH> <X>

63

REFSEL

This command selects or returns the output to be used as the EC Reference and PA (speaker output).

[DEVICE] REFSEL <X> <OUTPUT>

Explanation

 

Explanation

 

<CH>

 

<X>

 

CH= 1-4

Parameter to apply to the specified

X=1

Parameter to select the EC

 

microphone channel

 

Reference and PA (speaker

CH= *

Parameter to apply command to all microphone

 

output)

 

channels

X=2

Parameter to select the G-Link

<X>

 

 

EC Ref bus

X=0

Parameter to set the state to OFF

<OUTPUT>

 

X=1

Parameter to set the state to ON

OUTPUT=1-4

Parameter to select 1-4 as the

X=Null

Parameter to return the current state

 

EC reference and PA (speaker

 

 

 

output)

Return Values

OUTPUT=A-D

Parameter to select A-D as the

The command will return the updated condition (On=1, Off=0) of

 

EC reference and PA (speaker

the phantom power in the same format as the command.

 

output)

 

 

OUTPUT=E

Parameter to select G-Link EC

PRESET

 

 

Ref bus as the EC Reference and

 

 

PA (speaker output)

This command selects or reports the current preset configuration

OUTPUT=F

Parameter to select none

OUTPUT=Null

Parameter to return the EC

used by the AP400.

 

reference and PA (speaker

 

 

 

[DEVICE] PRESET <X>

 

output) value

Explanation

<X>

X=1-6

Sets the preset to the number specified

X=Null

Parameter to return the current preset

Return Values

The command will return the current preset. If the command changed the preset, the updated preset is returned.

Return Values

The command will return the updated condition of the reference and PA (speaker output) select in the same format as the command.