58

Appendices ~ Appendix E: Serial Commands

<OUTPUTMIX>

 

OUTPUTMIX=hex word

The selected input will be routed to

 

the outputs indicated.

OUTPUTMIX=null

Mix Command to return the current

 

setting for the input.

<OUTPUTMIX>Note:

When entering the hex value of the <OUTPUTMIX>, it is not necessary to add the leading zeros, only zeros that follow the value, as in examples 1 & 2, below.

Example 1

The following command routes Pregate Mic Input 1 audio to Output 1. This command applies only to the box the serial cable connects to, since a device is not specified.

Example 1. OUTPUTMIX matrix #34 MTRX 18 1

Example 2

The following command routes Mic Input 1 Post Gate audio to

Outputs A, B, and C, and to the G-Link X-bus.

Example 2. OUTPUTMIX matrix

MTRX 1 4700

Return Values

The command will return the updated condition of the matrix for the selected input in the same format as the command was issued.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 62
Image 62
ClearOne comm AP400 operation manual Outputmix, OUTPUTMIXNote, Return Values