Cognitive Solutions B780, A776 Continued, Programming commands, 3 = Transmit error status, Status

Models: B780 A776

1 192
Download 192 pages 23.55 Kb
Page 104
Image 104
92 Chapter 5: Programming commands

92 Chapter 5: Programming commands

2= Transmit RS-232C Busy Status Bit Status Hex Decimal Function

0

Off

00

0

Fixed to off.

1

On

02

2

Fixed to on.

2

Off

00

0

Receipt and cassette

 

 

 

 

cover closed.

 

On

04

4

Receipt or cassette cover

 

 

 

 

open.

3

Off

00

0

Paper feed button

 

 

 

 

is not pressed.

 

On

08

8

Paper feed button is pressed.

4

On

10

16

Fixed to on.

5

Off

00

0

Printing not stopped due

 

 

 

 

to paper condition.

 

On

20

32

Printing stopped due to

 

 

 

 

paper condition.

6

Off

00

0

No error condition.

 

On

40

64

Error condition exists in

 

 

 

 

the printer.

7

Off

00

0

Fixed to off.

3 = Transmit error status

 

 

 

 

 

 

Bit

Status

Hex

Decimal

Function

0

Off

00

0

Fixed to off.

1

On

02

2

Fixed to on.

2

Off

00

0

Carriage or slip jam

3

Off

00

0

No knife error.

 

On

08

8

Knife error occurred.

4

On

10

16

Fixed to on.

5

Off

00

0

No unrecoverable error.

 

On

20

32

Unrecoverable error occurred.

6

Off

00

0

Thermal printhead temp.

 

 

 

 

and power supply voltage

 

 

 

 

are in range.

 

On

40

64

Thermal print head temp.

 

 

 

 

or power supply voltage

 

 

 

 

are out of range.

7

Off

00

0

Fixed to off

Continued...

A776 (B780) Programming Guide

A776-PG00001 C 12/09

Page 104
Image 104
Cognitive Solutions B780 Continued, Programming commands, 2 = Transmit RS-232C Busy Status Bit Status Hex Decimal Function