Cognitive Solutions B780, A776 manual MICR commands, MICR reading, Read MICR data and transmit

Models: B780 A776

1 192
Download 192 pages 23.55 Kb
Page 126
Image 126
MICR commands

114 Chapter 5: Programming commands

Formulas

The waiting time is t × 100 ms for every macro execution.

m specifies macro executing mode when the LSB (least significant bit) m = 0

The macro executes r times continuously at the interval specified by t when the LSB (least significant bit) of m = 1.

Exceptions

If this command is received while a macro is being defined, the macro definition is aborted and the definition is cleared.

If the macro is not defined or if r is 0, nothing is executed.

MICR commands

MICR reading

These commands control the Magnetic Ink Character Recognition (MICR) check reader, including how it parses the character strings on checks.

The section, MICR parsing, describes how to create a parsing format and how to create and maintain an exceptions table.

Read MICR data and transmit

ASCII

ESC w 1

 

 

 

Hexadecimal

1B

77 01

A776:

1B 77 01

= read & transmit MICR, position for endorsement

 

1B

77 02 (B780 only)

B780:

1B 77 01

= wait for check, read & transmit MICR, eject check

Decimal

 

 

B780:

1B 77 02

= wait for check, read & transmit MICR, position for endorsement

27 119 1

 

 

 

Default:

All data returned

 

 

 

Reads and transmits the MICR data and adds a carriage return (0x0D). One status byte precedes the MICR characters.

If no parsing format is selected with either of the define parsing format commands (see below), all data will be returned, which is the default.

Status

 

Status byte value

 

 

 

 

Good read, data follows

 

0x00

 

Bad read, data follows

 

0x01

 

No check present, no data

 

0x02

 

Paper jam, no data

 

0x03

 

No MICR characters, no data

0x04

 

 

 

 

MICR characters

ASCII

Hexadecimal

 

 

 

Numerics

0 ... 9

0x30 ... 0x39

Unrecognized character

?

 

0x3F

Space

 

 

0x20

Amount symbol

&

 

0x26

Dash symbol

 

0x27

“on us” symbol

(

 

0x28

Transit symbol

)

 

0x29

A776 (B780) Programming Guide

A776-PG00001 C 12/09

Page 126
Image 126
Cognitive Solutions B780, A776 manual MICR commands, MICR reading, Read MICR data and transmit