Cognitive Solutions B780 manual A776 Emulation Commands, A776 Configuration Commands

Models: B780 A776

1 192
Download 192 pages 23.55 Kb
Page 22
Image 22
A776 Emulation Commands

10 Chapter 3: Migrating to a new printer

A776 Emulation Commands

Set Printer ID Mode Code (Hexadecimal) 1F 03 0C n

This command is ignored.

Set A776 Printer ID

Code (Hexadecimal)

1F 03 25 0F n

This command sets the printer ID response to the Printer ID command (1D 49 01)

n

Printer ID

00

A776

01

A760

02

A758

03

A756

Set A776 Printer Emulation

Code (Hexadecimal)

1F 03 25 02 n

n

Emulation

00

Native

01

A756 limited emulation (See list of comments earlier in this chapter)

A776 Configuration Commands

Select Slip Lines per Inch

Code (Hexadecimal)

1F 03 25 04 n

This command sets the slip station lines per inch setting.

n

Line spacing

00

7.2 LPI

01

6.0 LPI

Select Number of Lines of Validation

Code (Hexadecimal)

1F 03 25 06 n

This command sets the number of lines of validation that can be printed.

n

Number of validation lines

00

15

01-04

4 (default)

05-0F

actual number (5 - 15 decimal)

A776 (B780) Programming Guide