Cognitive Solutions B780, A776 manual Set GS1 DataBar formerly RSS parameters

Models: B780 A776

1 192
Download 192 pages 23.55 Kb
Page 114
Image 114
Set GS1 DataBar (formerly RSS) parameters

102 Chapter 5: Programming commands

m

Bar code

d1...dn

n

70

Interleaved 2 of 5 (ITF)

48–57

Variable (even number)

 

30-39

 

 

71

CODABAR (NW-7)

65–68, start code 48–57, 36, 43, 45, 46, 47, 58

Variable

 

 

41-44, start code 30-39, 24, 2B, 2D, 2E, 2F, 3A

 

72

Code 93

00–127

Variable

 

 

00-7F

 

73

Code 128

0–105 d1 = 103–105 (must be a start code)

Variable

 

 

d2 = 0–102 (data bytes) (Stop code is provided by the printer)

74

Code 128 auto compress

0-255

Variable

 

 

00-FF

 

75

PDF 417

0–255

Variable

 

 

00-FF

 

78

Code EAN 128 auto compress

0-255

Variable

 

 

00-FF

 

79

PDF 417

0-255

Variable

 

data length specified via

00-FF

0 < n < 2800

 

integer n = nH:nL

 

 

 

1D 6B m nL nH d1 . . . dn

 

 

The value of m selects the bar code system as described in the table. The variable d indicates the character code to be encoded into the specified bar code system. If character code d cannot be encoded, the printer prints the bar code data processed so far, and the following data is treated as normal data.

Exceptions

Illegal data cancels this command.

PDF 417 format cannot be printed on the slip.

Set GS1 DataBar (formerly RSS) parameters

Setting of parameters for GS1 Databar.

ASCII

GS q a b c d e fL fH

 

Hexadecimal

1D 71 a b c d e fL fH

 

Decimal

29 113 a b c d e fL fH

 

 

 

 

a

byte

pixels per minimum unit, default 3, minimum 2, maximum 6 (value a applies

 

 

to parameters b, c, d)

 

 

 

b

byte

X undercut, default 0, can be set 0 to a-1

 

 

 

c

byte

Y undercut, default 0, can be set 0 to a-1

 

 

 

d

byte

separator height, default a, can be set a to a*2

 

 

 

e

byte

segment width, used only by GS1 DataBar Expanded, default 22, must be

 

 

even number 2 to 22

 

 

 

f

word

line height, used only by UCC128, default 25, can be set 1 to 500

Note: For GS1 DataBar commands, consult ISO/IEC 24724. For further information, visit www.gs1.org.

A776 (B780) Programming Guide

A776-PG00001 C 12/09