Cognitive Solutions B780 Attach Scan Application Tags, Return Imager Status, Hexadecimal 1D B7

Models: B780 A776

1 192
Download 192 pages 23.55 Kb
Page 148
Image 148
Attach Scan Application Tags

136 Chapter 5: Programming commands

Decimal Value

Definition

297

Reserved for FW Page Number & Number of Pages p1= bottom scanner, p2= top scanner; these

 

are saved as type = two short integers

 

 

305

Application supplied string: Software = version description

306

FW supplied Date & 24 Hour Time of scan: 20 char YYYY:MM:DD:HH:MM:SS; must be application

 

initialized to start FW time stamping

 

 

33432

Application supplied string: Copyright

65000

Reserved for FW auto generated int FileIndex value

65001

Reserved for FW auto saved int of set transmission format parameter (m p r) values

65002

Reserved for FW auto saved raw MICR read string, if MICR present

 

 

65003

Reserved for FW auto saved int of entry point: 1 = slip, 2 = front

 

 

65004

Reserved for future FW auto saved reporting

 

 

65005

Reserved for FW auto save of parsed MICR string (if parsing has been defined)

65007-534

Any other Application set descriptions, usually strings, but any TIFF type

A few tag values that are useful to TIFF readers always have the default values and thus are not repeated in the returned structure. These are 266, Fill Order = 1; 274, Orientation = 1 (top left is 0,0); and 277, Samples Per Pixel = 1.

Attach Scan Application Tags

Hexadecimal: 1D B6

Parameters: None

Return: 1D 49 B6 m. M is 0 if OK, 1 if the scanned image already has application set tags or there is no last scanned image.

Description: Attach the current set of application defined tags to the last scanned image. This can be done only once to each image and allows the application to define tags up to image file transmission time. Note that this action takes place automatically in the case of the scan command with its parameter set for immediate transmission.

Return Imager Status

Hexadecimal: 1D B7

Parameters:

None

 

Return: 1D 49 B7 s m n pL pH rL rH

 

 

 

 

 

Value

 

Definition

 

 

 

 

 

1D

 

Command return indicator

 

 

 

 

 

49

 

Image Scanner

 

B7

 

Imaging function = status

s

 

Standard imaging status

 

 

 

 

 

 

 

Decimal

 

Meaning

 

 

 

 

 

 

 

0

 

OK

 

 

 

 

 

 

 

1

 

Jam detected

 

 

 

 

 

 

 

2

 

Wait for scan document cancelled

 

 

3

 

Imager cover open

 

 

7

 

Unrecoverable hardware error

 

 

 

 

 