SPECIFICATIONS

C

3 inch screen standard

A

5.5inch screen (optional)

B

 

MODEL

B32

 

Performance characteristics

 

 

Maximum number of vacuum receivers

32

 

Maximum number of vacuum pumps

8 (plus back-up)

 

Programmable logic controller

Allen Bradley Micrologix 1500

 

Touchscreen operator interface

Allen Bradley PV300 Micro

 

Communications with master control

DH485

 

Screen size, inches {mm}

2.87 X 1.67 {73 X 42}

 

User interface method

Keypad

 

Output voltage to receivers/valves

24 VDC

 

Sensor voltage to receivers

24 VDC

 

Output voltage to pumps

24 VDC

 

Dimensions inches {mm}

 

 

Master control cabinet

 

 

A - Height

31.4 {998}

 

B - Width

23.8 {606}

 

C - Depth

12.5 {318}

 

Weight lb {kg}

 

 

 

 

Installed

70 {32}

 

Shipping

85 {39}

 

Voltages Total amps

 

 

115V/1 phase/60Hz (master control)

10

 

 

 

SPECIFICATION NOTES:

B32 loader control cable: 18 gauge shielded, 8-conductor may be used for standard vacuum receivers with up to one optional output and input, otherwise 10-conductor cable is required.

Specifications can change without notice. Check with your Conair representative for the most current information.

APPLICATION NOTES:

Conair vacuum receivers come equipped with a quick-disconnect connector set that includes 10 feet of cable. Junction boxes must be provided to connect the system cable and each vacuum receiver’s connector set.

CALCULATING CABLE LENGTH:

Total the distances from the Input/output Station(s) location to each vacuum receiver on the system. Be sure to account for reasonable slack at each loading station for connections, cable routing, etc.

2-4

DESCRIPTION

Basic 32 Loader Control

UGC007/0702