WARNING: Develop and follow procedures for safe operation of the system to avoid possible injury or equipment damage.

The B32 allows operators and maintenance personnel to disable and enable conveying system components from remote locations. Unexpected energization of these components could result in equipment damage or injury.

Safe operating procedures should include:

rDisconnect any loader, pump or material valve from main power and/or compressed air sources before servicing. Ensure that all energy sources for the device are locked out and tagged.

rBefore removing lockout devices or enabling pumps, loaders or material valves, make sure that all personnel are clear of the machine, tools have been removed and any safety guards have been reinstalled.

To enable the pumps from the main screen:

1 Use the Up/Down arrows to scroll to

Loader Settings.

2 Press the Enter arrow.

The Loader Settings screen displays. Use the up/down arrows to scroll to Pump Enable.

3 Press the Enter arrow.

The Pump Enable screen displays. Use the up/down arrows to increase and decrease the pump number. Use the scroll down/up buttons to enable/disable the pump.

NOTE: When a pump is disabled the loader completes its load cycle before the pump is de-energized.

4 Press the Enter arrow to save the change.

5 Press the Previous button to return to

the last screen you were viewing, or the Main button to return to the Main screen.

ENABLING

AND DISABLING

PUMPS

UGC007/0702

Basic 32 Loader Control

OPERATION 4-5