CAUTION: Incorrect configurations will cause the B32 control to stop.
Before enabling loaders and loading functions, make sure the loader, valve or option has been installed in the system. Each loader and feature must be wired to a correctly installed and enabled input or output module. The B32 will fault and the loading control will stop if the required I/O module has not been installed for the feature you enabled.
The loader must be correctly installed and wired before setting parameters.
To set loader parameters from the main screen:
1 Use the Up/Down arrows to scroll to
Loader Settings.
2 Press the Enter arrow.
The Loader Settings screen displays. Use the up/down arrows to scroll to Settings.
3 Press the Enter arrow.
The Settings screen displays. Use the left/right arrows to scroll to move the cursor to the Loader field. Use the up/down arrows to select loader.
4 Use the Scroll Down/Up buttons to set the loader
parameters: loader number, virgin time in seconds, dump time in seconds and pump number.
Basic 32 Loader Control | UGC007/0702 |