C-2Troubleshooting Your System

When Operating Normally

The POWER and RUN LEDs are on. If a force condition is active, the FORCE

LED turns on and remains on until all forces are removed.

When an Error Exists

If an error exists within the controller, the controller LEDs operate as described in the following tables.

If the LEDS

The Following

Probable Cause

Recommended Action

indicate:

Error Exists

 

 

 

 

 

 

All LEDS off

No input power or

No Line Power

Verify proper line voltage and

 

power supply error

 

connections to the controller.

 

 

 

 

 

 

Power Supply

This problem can occur intermittently if

 

 

Overloaded

power supply is overloaded when output

 

 

 

loading and temperature varies.

 

 

 

 

Power and

Hardware faulted

Processor

Cycle power. Contact your local

FAULT LEDs

 

Hardware Error

Conair Service representative if

on solid

 

 

the error persists.

 

 

 

 

 

 

Loose Wiring

Verify connections to the controller.

 

 

 

 

Power LED

Application fault

Hardware/

4. Monitor Status File Word S:6 for

on and

 

Software Major

major error code. See page C-4 for

FAULT LED

 

Fault Detected

more information.

flashing

 

 

5. Remove hardware/software

 

 

 

condition causing fault.

 

 

 

6. Clear Major Error Halted flag, bit

 

 

 

S2:1/13.

 

 

 

7. Attempt a controller Run mode entry.

 

 

 

If unsuccessful, repeat recommended

 

 

 

action steps above or contact your

 

 

 

Coniar Servicerepresentative.

 

 

 

 

Basic 32 Loader Control UGC007/0702