Alarm

Possible cause Solution

No Material Alarm

Vacuum pump is not

(continued)

working correctly.

Verify that the vacuum pump is on, connected to the B32 and working correctly. Refer to the pump manual.

The fill/demand sensor or demand switch is not working properly.

Compressed air lines are not connected correctly.

Pump Overload

The vacuum pump

 

overload has tripped.

rVerify that sensors and switches are connected correctly at the loader or hopper and at the control.

rVerify that fill and demand sensors are set at the correct height and adjusted proper- ly. Refer to manuals sup- plied with the fill or demand signaling device.

If a compressed air line is not connected to vacuum or material valves, the valves cannot open to allow the pump to draw material into the receiver. Verify that compressed air lines supplying the correct pressure have been connected to the vacuum sequencing valve, ratio valve, pocket conveying or purge valve.

This alarm will prevent the pump from being energized until the overload is corrected. Refer to the pump manual to correct the problem.

UGC007/0702

Basic 32 Loader Control

TROUBLESHOOTING 6-7