Connect Tech Blue Heat/Net Sync User Manual
| [my_ip= mip=] |
| [server_ip= sip=] |
| [gateway_ip= gip=] |
| [subnetmask= snm=] |
| [broadcast_ip= bcip=] |
| [dns_ip=] |
| [domain=] |
| [host name=1 host=] |
| [tcp=] |
| [mac=] |
| [dhcp=] |
Description: | Establishes the network settings. |
Options: | network= net= |
| Sets the “network” portion of the IP address into my_ip, server_ip and |
| gateway_ip. The address entered is masked by the subnet mask setting before |
| being applied. This command is a shortcut for quickly setting all the IP |
| addresses of the unit. See note below. |
| my_ip= mip= |
| This sets the IP address of the Blue Heat/Net Sync unit (default is 192.168.42.1). |
| See note below. |
| server_ip= sip= |
| This sets the Server IP address. This address determines the address of the |
| Server to use when the Bootp and tftp mode is enabled (see boot command), and |
| also as the default Server address to use for the update commands (default is |
| 0.0.0.0). See note below. |
| gateway_ip= gip= |
| This sets the Gateway IP address. This address is used when the Bootp mode is |
| enabled, default is 0.0.0.0. See note below. |
| subnetmask= snm= |
| This sets the Subnet mask IP address. (The default is 255.255.255.0) See note 1. |
| broadcast_ip= bcip= |
| This sets the Broadcast IP address. This is used when the Bootp mode is |
| enabled. (The default 255.255.255.255). See note below. |
| dns_ip= |
| This sets the IP of Domain Name Server. (The default is 0.0.0.0). This must be |
| set to update the Blue Heat/Net Sync firmware automatically from Connect |
| Tech‟s anonymous ftp server. |
| domain= |
| This sets the Domain name of the unit. (The default is blueheat.net) |
| Host name=1 host = |
| This sets the Host name of the Blue Heat/Net Sync unit. (The default is |
| BHNssssssss, where “ssssssss” is the serial number of the unit). |
| tcp= |
| This sets the base TCP port number used for Host TCP/IP and UDP/IP |
| communications. The default is 49152 (0xC000) |
28 | Revision 0.03 |