Connect Tech Blue Heat/Net Sync User Manual
52 Revision 0.03
Address
Offset
(in hex)
Area (item)
Accessed
Register
Accessed
Notes
Writes go to the Transmitter FIFO
Reads come from the Receiver FIFO
022
IUSC-0 Sreg
RMR
024
IUSC-0 Sreg
RCSR
026
IUSC-0 Sreg
RICR
028
IUSC-0 Sreg
RSR
02A
IUSC-0 Sreg
RCLR
02C
IUSC-0 Sreg
RCCR
02E
IUSC-0 Sreg
TCOR
030
IUSC-0 Sreg
TDR(RDR)
8/16 bit Serial Data (byte/word)
Writes go to the Transmitter FIFO
Reads come from the Receiver FIFO
032
IUSC-0 Sreg
TMR
034
IUSC-0 Sreg
TCSR
036
IUSC-0 Sreg
TICR
038
IUSC-0 Sreg
TSR
03A
IUSC-0 Sreg
TCLR
03C
IUSC-0 Sreg
TCCR
03E
IUSC-0 Sreg
TC1R
040 07F
---
---
Aliases of addresses 00 3F
080->09F
IUSC
Data FIFO‟s
(32 bytes)
RDR/TDR
16 bit Serial Data transfers ONLY!!
Writes go to the Transmitter FIFO
Reads come from the Receiver FIFO
(useful for block data movements)
0A0 0FE
Aliases of 080->9F
100
IUSC-0 Dreg [2]
DCAR
102
IUSC-0 Dreg
TDMR
104
---
---
Reserved, do not access
106
IUSC-0 Dreg
DCR
108
IUSC-0 Dreg
DACR
10A 111
---
---
Reserved, do not access
112
IUSC-0 Dreg
BDCR
114
IUSC-0 Dreg
DIVR
116
---
---
Reserved, do not access
118
IUSC-0 Dreg
DICR
11A
IUSC-0 Dreg
CDIR
11C
IUSC-0 Dreg
SDIR
11E
IUSC-0 Dreg
TDIAR
120 129
---
---
Reserved, do not access
12A
IUSC-0 Dreg
TBCR
12C
IUSC-0 Dreg
TARL
12E
IUSC-0 Dreg
TARU
130 139
---
---
Reserved, do not access
13A
IUSC-0 Dreg
NTBCR
13C
IUSC-0 Dreg
NTARL
13E
IUSC-0 Dreg
NTARU
140 181
---
---
Reserved, do not access
182
IUSC-0 Dreg
RDMR
184 19D
---
---
Reserved, do not access
19E
IUSC-0 Dreg
RDIAR