Connect Tech Blue Heat/Net Sync User Manual

 

Serial Mode (smode)

 

 

Async

 

 

MonoSync

 

 

BiSync

 

 

Trans-BiSync

 

 

HDLC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BHN_PortSettings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sync_addr.rx0

 

 

 

 

 

Required

 

 

Required

 

 

Required

 

 

Required

 

sync_addr.rx1

 

 

 

 

 

 

 

 

Required

 

 

Required

 

 

Optional

 

sync_addr.rx_len

 

 

 

 

 

Required

 

 

Required

 

 

Required

 

 

 

 

 

sync_addr.strip_sync

 

 

 

 

 

Optional

 

 

Optional

 

 

Optional

 

 

 

 

 

dbits.t/rx

 

 

Required

 

 

Required

 

 

Required

 

 

Required

 

 

Required

 

tx_frac_stop

 

 

Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parity.t/rx

 

 

Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

crc.tx_type

 

 

 

 

 

Required

 

 

Required

 

 

Required

 

 

Required

 

crc.tx_start

 

 

 

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

crc.tx_mode

 

 

 

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

crc.rx_type

 

 

 

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

crc.tx_start

 

 

 

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

 

Optional [6]

 

tx_trig_gate

 

 

Required

 

 

Required

 

 

 

 

 

 

 

 

 

 

 

rx_gate

 

 

Required

 

 

Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Required [1]: Must be NRZ or NRZ_INV

Optional [1]: Needed if a clocking source feeds either of the Baud Rate Generators. If the Receiver or Transmitter are clocked directly from certain Line Interface signals (RxC or TxC setup as inputs) and those Interface signals are setup as outputs, then the indicated parameters are required.

Optional [2]: Required only when the DPLL is part of the clocking tree setup.

Optional [3]: Required only when either Counter (CTR-0 or CTR-1) is directly clocking the Receiver, Transmitter, RxC or TxC signals.

Optional [4]: Only required when the clk_tree.A setting is CLK_DPLL (which is generally only used with Synchronous modes).

Optional [5]: Only required when the clk_tree.A or clk_tree.C setting selects a Baud Rate generator.

Optional [6]: Only required if CRC is enabled.

60

Revision 0.03

Page 60
Image 60