5300381000
INSTALLATION
This section coversunpacking and inspection,selecting location,installing Cooling Unit, preparing foroperation,
and operation.

UNPACKINGAND INSPECTION

NOTE:TheCooling Unitwas thoroughlyinspected beforeleaving thefactory and the carrierhas
acceptedand signedforit.Anydamageorirregularities should benotedat timeofdelivery(ornotlater
than15 days fromdateofdelivery)and immediatelyreportedtothedelivering carrier.Requestawritten
inspection report fromClaimsInspectortosubstantiate anynecessary claim.File claimwiththe
delivering carrier,notwithIMICorneliusInc.
1.AfterCooling Unithasbeen unpacked,removeshipping tape and otherpacking material.
2.Unpack LOOSE-SHIPPEDPARTS.Makesureall itemsare presentand in good condition.
Table 2.Loose-ShippedParts
Item
No.PartNo.NameQty.
1 110085000 Tubing Clamp 2
2 111353000 Tubing Clamp 7
3 311962000 Label,Line Identification 1
NOTE:Thefollowing RemoteCondenserCoil and FanAssembly and Refrigeration Lines Kits arerec-
ommendedforuse withtheCooling
Units.
4 309602000 RemoteCondenserCoil and Fan Assy1
5 300598025 Refrigeration Line Kit, 25-ft. long,90°1
300598050 Refrigeration Line Kit, 50-ft. long,90°Straight1

IDENTIFICATIONOF LOOSE-SHIPPEDPARTS

1.TUBINGCLAMPS (item1)used tosecureinsulated python linestoCooling Unitcarbonated wateroutlet
lines.
2.TUBINGCLAMPS (item2)used tosecureinsulated python linestoCooling Unitsyrup and plainwater
lines.
3.REFRIGERATIONLINE KITS(item5)isused toconnect the REMOTECONDENSER COILAND FAN
ASSY(item4)tothe Cooling Unit.

SELECTINGLOCATION

COOLINGUNIT

Selectlocation forCooling Unitinstallation thatwill (1)Allowthe shortestpossibleinsulated python routefrom
the Cooling Unit tothe Dispensing Station location;(2)Allowthe shortestpossiblerefrigeration lines(not to
exceed 50-ft inlength) routefromRemoteCondenserCoil and Fan Assemblytothe Cooling Unit; (3)REFER
TOTHECOOLINGUNITNAMEPLATEFORTHEREQUIREDPOWERCIRCUITOPERATINGVOLTAGE,HZ,
AND THEMINIMUMCIRCUITAMPACITYOF THECOOLINGUNIT.The powercircuitforthe Cooling Unit
mustbe wired through a 40-ampminimumrated disconnectswitch(notprovided)and the powercircuitmustbe