CONNECTING COOLING UNIT SYRUP OUTLET LINES TO INSULATED PYTHON SYRUP LINES

(see Figure 2)

Connect Cooling Unit syrup outlet lines labeled No. 1 through No. 6, with barbed fittings on their ends, to insulated python lines labeled No. 1 through No. 6. Secure connections with TUBING CLAMPS (item 2).

CONNECTING COOLING UNIT PLAIN WATER OUTLET LINE TO INSULATED PYTHON PLAIN WATER LINE

(see Figure 2)

NOTE: Shutoff valve in plain water line inside Cooling Unit must remain closed if plain water is not desired at dispensing valve.

Connect Cooling Unit plain water outlet line, with barbed fitting on its end, to insulated python plain water line. Secure connection with TUBING CLAMP (item 2).

CONNECTING COOLING UNIT CARBONATED WATER OUTLET LINES TO INSULATED PYTHON CARBONATED WATER LINES

(see Figure 2)

Connect Cooling Unit carbonated water outlet lines, with barbed connectors on their ends, to insulated python carbonated water lines. secure Connections with TUBING CLAMPS (item 1).

PLACING COOLING UNIT IN OPERATING POSITION

1.Very carefully, move Cooling Unit back into operating position leaving space around unit (see Figure 4) as specified in SELECTING LOCATION. MAKE SURE THERE ARE NO KINKS IN SYRUP INLET LINES,

INSULATED PYTHON INTERNAL LINES, CO2 AND PLAIN WATER INLET LINES, AND REMOTE CONDENSER AND FAN ASSEMBLY REFRIGERATION LINES (IF APPLICABLE).

NOTE: To comply with National Sanitation Foundation (NSF) requirements, Cooling Unit not installed on optional Cooling Unit Stand (P/N 309309069) must have its base sealed to floor with Dow-Corning RTV 731 or equivalent.

1.Tilt Cooling Unit up to expose bottom of unit base.

2.Liberally apply silastic sealant such as Dow Corning (RTV 731) or equivalent on unit base bottom edges.

NOTE: Do not move Cooling Unit after positioning or seal from unit base to floor will be broken.

 

18-IN.

18-IN.

COOLING UNIT

18-IN.

AIR FLOW

(OPEN TO ROOM)

FIGURE 4. COOLING UNIT SPACE REQUIRED

300381000