SANITIZING POST-MIX SYRUP SYSTEMS

IMPORTANT: Only qualified Service Personnel should perform sanitizing procedure on the post-mix syrup systems.

The post-mix syrup systems should be sanitized every 90-days using a non-scented household liquid bleach containing a 5.25 % sodium hypochlorite concentration. Proceed as follows to sanitize the post-mix syrup systems.

1.Disconnect syrup supplies from syrup systems.

2.Rinse quick disconnects (syrup tanks systems) or bag-in-box connectors (syrup bag-in-box systems) in warm potable water.

STEP 1. WASH SYRUP SYSTEMS

3.Using a clean syrup tank (syrup tank system) or a five-gallon container (bag-in-box system), prepare a full tank or container of liquid dishwasher detergent by using 70_F (21_C) to 100_F (38_C) potable water and 0.5 oz. (15 ml) of liquid dishwasher detergent to one gallon of potable water. Stir detergent solution to thoroughly mix the solution.

4.Syrup Tank Systems.

A.Observe and note CO2 pressure setting on the syrup tanks CO2 regulator, then re-adjust CO2 regulator to 60 to 80-psi. Pressurize syrup tank containing detergent solution to 60 to 80-psi.

B.Connect detergent solution tank, pressurized at 60 to 80-psi, into one of the syrup systems.

Bag-in Box Syrup Systems.

C.Install bag valves, cut from empty bag-in-box syrup containers, on ends of syrup containers syrup outlet tubes connectors.

D.Place all syrup outlet tubes, with bag valves on their ends, in container containing detergent solution.

5.Flush the syrup system and dispensing valve as follows:

A.Place waste container under applicable dispensing valve.

B.Activate the dispensing valve for one minute to purge all syrup and flush out the syrup system.

C.Continue to activate the dispensing valve in cycles (“ON”for 15-seconds, “OFF”, then “ON”for 15-seconds). Repeat “ON”and “OFF”cycles for 15-cycles.

6.Connect detergent solution to the remaining syrup systems and flush syrup out of the syrup systems as instructed in step NO TAG preceding.

7.Remove detergent solution source from the syrup system.

STEP 2. FLUSH SYRUP SYSTEMS

8.Syrup Tank Systems.

Connect syrup tank containing potable water, pressurized at 60 to 80-psi, into one of the syrup systems.

Bag-in-Box Syrup System.

Fill five-gallon container with potable water, then place all bag-in-box syrup containers syrup outlet tubes in container containing potable water.

9.Flush detergent solution out of the syrup system and dispensing valve as follows:

A.Place waste container under applicable dispensing valve.

B.Activate the dispensing valve for one minute to purge all detergent solution and flush out the syrup system.

29

300381000

Page 34
Image 34
Cornelius 10, 000 installation manual Sanitizing POST-MIX Syrup Systems, Wash Syrup Systems, Flush Syrup Systems

000, 10 specifications

Cornelius 10,000 PLUS is a pioneering innovation in the beverage dispensing industry, designed to cater to the evolving needs of commercial establishments. This advanced system combines state-of-the-art technology with user-friendly features, making it a standout choice for restaurants, cafes, and bars aiming to enhance their beverage service.

One of the main features of the Cornelius 10,000 PLUS is its impressive capacity. With the ability to dispense a wide variety of beverages, including soft drinks, cocktails, and craft beers, the system supports a large volume of service, perfect for high-demand environments. The modular design allows for easy expansion, enabling businesses to add additional flavors or beverages as needed without major overhauls.

The technology behind the Cornelius 10,000 PLUS is equally impressive. It utilizes advanced cooling technology to ensure that beverages are served at the optimal temperature, enhancing the customer experience. The integrated touchless dispensing mechanism minimizes waste and ensures a hygienic experience, addressing growing concerns about cleanliness in food service environments. This technology also improves speed, allowing staff to serve customers more efficiently.

Another key characteristic of the Cornelius 10,000 PLUS is its digital integration capabilities. The system can be connected to a central management platform that tracks sales, inventory levels, and maintenance needs in real-time. This allows operators to optimize their beverage offerings based on customer preferences and reduces downtime through proactive maintenance alerts.

In addition to its performance features, the Cornelius 10,000 PLUS is designed with sustainability in mind. The system employs energy-efficient practices, reducing its environmental footprint while lowering operational costs. The materials used in construction are durable yet eco-friendly, ensuring longevity and less waste.

Overall, the Cornelius 10,000 PLUS stands out as an essential tool for any business looking to elevate its beverage service. With its combination of high capacity, cutting-edge technology, and sustainability features, it not only meets the demands of today’s fast-paced service environments but also positions establishments for future growth and success.