300381000 12
STARTINGCOOLINGUNITREFRIGERATIONSYSTEM
NOTE:Asice bankformsinwatertank,waterexpansion will take place and excess waterwill escape
through watertankoverflowhose to permanent floordrain.
Cooling UnitConnected ToRemoteCondenserCoiland Fan Assembly.(P/N309602000).
PlaceCooling UnitREFRIGERATIONPOWERswitchin‘‘ON’’(up)position.Refrigeration compressor,
compressorcooling fan,agitatormotor,and RemoteCondenserCoil and Fan Assemblywill start. Cooling Unit
will beginforming an ice bankand refrigerated HydroBoostâcoil will alsobechilling water.Whenfull ice bank
hasbeen formed,RemoteCondenseroil and Fan Assembly,Cooling Unitcompressor,andcompressorcooling
fan will stop butagitatormotorwill continue to operatecirculating icewaterbathinwatertank.
StandardCooling UnitUtilizing CondenserCoil and Fan Assembly.
PlaceCooling UnitREFRIGERATIONPOWERswitchin‘‘ON’’(up)position.Refrigeration compressor,
condenserfan motor,and agitatormotorwill startand beginforming an ice bank.When full ice bankhasbeen
formed,compressorand condenserfan motorwill stop but, agitatormotorwill continue to operatecirculating ice
waterbathinwatertank.
STARTINGCARBONATEDWATER CIRCULATINGPUMP
1.PlaceCIRCULATINGMOTORpowerswitchin‘‘ON’’(up)position.Circulating pumpwill startand begin
circulating carbonated waterinsystem.
2.Dispensecarbonated waterfromdispensing valvetomakesure all airhasbeen purged fromsystem.
3. If Cooling Unitplainwateroutletline is connected to dispensing system,open plainwatershutoff valve
inside unit. Dispensefromvalve until all airispurged fromplainwatersystem.
ACTIVATINGSYRUPSYSTEMS
1.Adjustsoft drinktanks secondaryCO2regulators(see Figure 2)asfollows:
SugarSyrup Soft DrinkTanksCO2Regulator.
Adjustsugarsyrup soft drinktanks secondaryCO2regulatorat40-psigforsyrup linesup to 10-feetin
length plusone pound foreach additional length of10-feet, plusone pound foreach 2-feetofvertical lift.
Forexample:ifsyrup line total lengthis30-feetand totalvertical lift is6-feet, then 40-psig+2-psig
(1-pound forevery10-feetoflength over10-feetwhichis20-feet)+3-psig(1-pound forevery2-feetof
vertical lift whichis6-feet); totalequals40 +2+3=45-psigCO2regulatorsetting.
Low-Calorie(diet)Syrup Soft DrinkTankCO2Regulator.
Adjustlow-calorie(diet)soft drinktank secondaryCO2regulatorforlow-calorie drinkat10-psigforsyrup
linesup to 30-feetinlength.Syrup lineslongerthan 30-feetinlengthmayrequireaslightlyhigherCO2
regulatorsetting to 12-psigmaximum.ExcessiveCO2pressuremay causelow-caloriesyrup carbonation
resulting infoam.
IMPORTANT:Syrupsystemsmustbe sanitizedas instructed before syrup is connectedintosyrup
systems.
2.Connectsoft drinktanks intosyrup systems.
3.Dispensefromall dispensing stationsdispensing valvesuntil productisdispensed.