Trouble

Probable Cause

Remedy

ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW REGULATOR DOES NOT DECREASE TO DESIRED WATER-TO-SYRUP ‘RATIO’.

A.Dirty or inoperative piston or cylinder in dispensing valve syrup flow regulator.

A.Disassemble and clean dispensing valve syrup flow regulator.

DISPENSED PRODUCT

A. Carbonator CO2 regulator out

CARBONATION TOO LOW.

of adjustment for existing

 

water conditions or

 

temperature.

A.Adjust carbonator CO2 regulator as instructed.

B.Water, oil, or dirt in CO2 supply.

B.Remove contaminated CO2 supply. Clean CO2 system (lines, regulators,etc.) using a mild detergent. Replenish with a clean CO2 supply.

DISPENSED PRODUCT

A. Oil film or soap scum in cups. A. Use clean cups.

COMES OUT OF

 

DISPENSING VALVE CLEAR

 

BUT FOAMS IN CUP.

 

B.Ice used for finished drink is sub-cooled.

B.Do not use ice directly from freezer. Allow ice to become ‘wet’ before using. (Refer to following NOTE)

NOTE: Crushed ice also causes dispensing problems. When finished drink hits sharp edges of ice, carbonation is released from finished drink.

DISPENSED PRODUCT PRODUCES FOAM AS IT LEAVES DISPENSING VALVE.

A.Carbonator CO2 regulator pressure set too high for existing water conditions or temperature.

A.Reduce carbonator CO2 regulator pressure setting as instructed.

B.Syrup over-carbonated with CO2.

C.Tapered nylon washer inside tube swivel nut connection distorted from being overtightened restricting syrup flow.

B.Remove soft drink tank quick

disconnects. Relieve tank CO2 pressure, shake tank vigorously,

then relieve tank CO2 pressure as many times as necessary to remove over-carbonation.

C.Replace nylon washer. Make sure washer is properly seated in swivel nut.

ONLY CARBONATED WATER A.

Quick disconnect not secure

A.

Secure quick disconnect on soft

DISPENSED.

on soft drink tank.

 

drink tank.

B.

Out of syrup.

B.

Replenish syrup supply as

 

 

 

instructed.

C.Inoperable dispensing station.

D.Dispensing valve syrup flow regulator not properly adjusted.

C.Repair dispensing station.

D.Adjust dispensing valve syrup flow regulator (refer to Installation Instructions provided with dispensing station).