Cypress CY14B104K, CY14B104M manual 0x7FFF2 0x3FFF2 Alarm Seconds, Centuries 0x7FFF0 0x3FFF0 Flags

Models: CY14B104K CY14B104M

1 31
Download 31 pages 36.6 Kb
Page 13
Image 13

 

 

 

 

 

 

PRELIMINARY

 

 

CY14B104K, CY14B104M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5. Register Map Detail (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register

 

 

 

 

 

Description

 

 

 

 

 

 

CY14B104K

CY14B104M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x7FFF4

 

0x3FFF4

 

 

 

 

 

Alarm - Hours

 

 

 

 

 

 

 

D7

D6

 

D5

 

D4

 

D3

 

D2

 

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

10s Alarm Hours

 

 

 

 

Alarm Hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contains the alarm value for the hours and the mask bit to select or deselect the hours value.

 

 

 

 

 

M

 

 

 

Match. When this bit is set to 0, the hours value is used in the alarm match. Setting this bit to 1

 

 

 

 

 

causes the match circuit to ignore the hours value.

 

 

 

 

 

 

 

 

0x7FFF3

 

0x3FFF3

 

 

 

 

 

Alarm - Minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

 

D5

 

D4

 

D3

 

D2

 

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

10s Alarm Minutes

 

 

 

 

Alarm Minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contains the alarm value for the minutes and the mask bit to select or deselect the minutes value.

 

 

 

 

 

M

 

 

 

Match. When this bit is set to 0, the minutes value is used in the alarm match. Setting this bit to 1

 

 

 

 

 

causes the match circuit to ignore the minutes value.

 

 

 

 

 

 

 

 

0x7FFF2

 

0x3FFF2

 

 

 

 

 

Alarm - Seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

 

D5

 

D4

 

D3

 

D2

 

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

10s

Alarm Seconds

 

 

 

Alarm Seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contains the alarm value for the seconds and the mask bit to select or deselect the seconds’ value.

 

 

 

 

 

M

 

 

 

Match. When this bit is set to 0, the seconds value is used in the alarm match. Setting this bit to

 

 

 

 

 

1 causes the match circuit to ignore the seconds value.

 

 

 

 

 

 

0x7FFF1

 

0x3FFF1

 

 

 

Time Keeping - Centuries

 

 

 

 

 

 

 

D7

D6

 

D5

 

D4

 

D3

 

D2

 

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10s

Centuries

 

 

 

 

 

Centuries

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contains the BCD value of centuries. Lower nibble contains the lower digit and operates from 0

 

 

 

 

 

to 9; upper nibble contains the upper digit and operates from 0 to 9. The range for the register is

 

 

 

 

 

0-99 centuries.

 

 

 

 

 

 

 

 

 

 

 

 

 

0x7FFF0

 

0x3FFF0

 

 

 

 

 

Flags

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

 

D5

 

D4

 

D3

 

D2

 

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WDF

AF

 

PF

 

OSCF

 

0

 

CAL

 

W

 

R

 

 

 

 

 

 

 

 

 

 

 

 

WDF

 

 

 

Watchdog

Timer Flag.

This read only bit is set to 1 when the watchdog timer is allowed to reach

 

 

 

 

 

0 without being reset by the user. It is cleared to 0 when the Flags register is read or on power up

AF

 

 

 

Alarm Flag. This read only bit is set to 1 when the time and date match the values stored in the

 

 

 

 

 

alarm registers with the match bits = 0. It is cleared when the Flags register is read or on power up.

PF

 

 

 

Power Fail Flag. This read only bit is set to 1 when power falls below the power fail threshold

 

 

 

 

 

VSWITCH. It is cleared to 0 when the Flags register is read or on power up.

 

 

 

 

OSCF

 

 

 

Oscillator Fail Flag. Set to 1 on power up if the oscillator is enabled and not running in the first 5

 

 

 

 

 

ms of operation. This indicates that RTC backup power failed and clock value is no longer valid.

 

 

 

 

 

This bit survives power cycle and is never cleared internally by the chip. The user must check for

 

 

 

 

 

this condition and write '0' to clear this flag.

 

 

 

 

 

 

 

 

CAL

 

 

 

Calibration Mode. When set to 1, a 512 Hz square wave is output on the INT pin. When set to 0,

 

 

 

 

 

the INT pin resumes normal operation. This bit defaults to 0 (disabled) on power up.

W

 

 

 

Write Enable: Setting the W bit to 1 freezes updates of the RTC registers. The user can then write

 

 

 

 

 

to RTC registers, Alarm registers, Calibration register, Interrupt register and Flags register. Setting

 

 

 

 

 

the W bit to 0 causes the contents of the RTC registers to be transferred to the time keeping

 

 

 

 

 

counters if the time has been changed (a new base time is loaded). This bit defaults to 0 on power

 

 

 

 

 

up.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

Read Enable: Setting R bit to 1, stops clock updates to user RTC registers so that clock updates

 

 

 

 

 

are not seen during the reading process. Set R bit to 0 to resume clock updates to the holding

 

 

 

 

 

register. Setting this bit does not require W bit to be set to 1. This bit defaults to 0 on power up.

Document #: 001-07103 Rev. *K

 

 

 

 

 

 

 

 

 

 

 

 

Page 13 of 31

[+] Feedback

Page 13
Image 13
Cypress CY14B104K, CY14B104M 0x7FFF2 0x3FFF2 Alarm Seconds, Centuries 0x7FFF0 0x3FFF0 Flags, Document # 001-07103 Rev. *K