CY8C23433, CY8C23533
Absolute Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the device. User guidelines are not tested.
Table 9. Absolute Maximum Ratings
Symbol | Description | Min | Typ | Max | Units | Notes |
TSTG | Storage Temperature | 25 | +100 | °C | Higher storage temperatures | |
|
|
|
|
|
| reduce data retention time. |
|
|
|
|
|
| Recommended storage |
|
|
|
|
|
| temperature is +25°C ± 25°C. |
|
|
|
|
|
| Extended duration storage |
|
|
|
|
|
| temperatures above 65°C |
|
|
|
|
|
| degrade reliability. |
TA | Ambient Temperature with Power Applied | – | +85 | °C |
| |
Vdd | Supply Voltage on Vdd Relative to Vss | – | +6.0 | V |
| |
|
|
|
|
|
|
|
VIO | DC Input Voltage | Vss - 0.5 | – | Vdd + 0.5 | V |
|
VIOZ | DC Voltage Applied to | Vss - 0.5 | – | Vdd + 0.5 | V |
|
IMIO | Maximum Current into any Port Pin | – | +50 | mA |
| |
ESD | Electro Static Discharge Voltage | 2000 | – | – | V | Human Body Model ESD. |
|
|
|
|
|
|
|
LU | – | – | 200 | mA |
| |
|
|
|
|
|
|
|
Operating Temperature
Table 10. Operating Temperature
Symbol | Description | Min | Typ | Max | Units | Notes |
TA | Ambient Temperature | – | +85 | °C |
| |
TJ | Junction Temperature | – | +100 | °C | The temperature rise from | |
|
|
|
|
|
| ambient to junction is package |
|
|
|
|
|
| specific. See Thermal Imped- |
|
|
|
|
|
| ances by Package on page 35. |
|
|
|
|
|
| The user must limit the power |
|
|
|
|
|
| consumption to comply with this |
|
|
|
|
|
| requirement. |
Document Number: | Page 15 of 37 |
[+] Feedback