1.Scan the bar code beside Intercharacter Delay = XX and lis- ten for one short-high beep.

2.After the beep, scan the bar code beside 0 on the Digit Selec- tion page and listen for one short-high beep.

3.Still at the Digit Selection page, scan the bar code for 5 (the last argument in the command) and listen for two short beeps.

Your PSC scanner does not have a distinct programming mode. Instead, it automatically recognizes and reacts to the labels you scan. If, for example, you scan INTERCHARACTER DELAY = XX and then scan a normal data label, a normal tone is emitted in response to the data label, and the programming command is ignored. No special exit code is required to resume normal operations.