Code 2 of 5 – Interleaved

Scan Option PA to disable Interleaved Code 2 of 5.

PA

Disable Interleaved Code 2 of 5*#@

Scan Option PB or PC to enable Interleaved Code 2 of 5.

PB

PC

Enable Interleaved 2 of 5 without Check Digit

Enable Interleaved 2 of 5 with Check Digit

The minimum length of Interleaved 2 of 5 messages is set by scanning Option PD, followed by scanning two digits (02-32) from the Digit Selection page. The value of the number you scan must be even.

PD

Minimum Length I 2 of 5 (specified by two digits 02-32)

The maximum length of Interleaved Code 2 of 5 is set by scanning Option PE, followed by scanning two digits (02-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read. The minimum and maximum lengths must be even numbers.

PE

Maximum Length I 2 of 5 (specified by two digits 02-32)

46

User’s / Programming Guide

Page 54
Image 54