Label Buffering

The user may select one of three levels of serial buffering. With Full Buffering (the default) selected, the scanner will place all scanned labels into a buffer for transmission. This allows the operator to con- tinue scanning even though the previous label may not have been transmitted yet. Scanning will continue normally until the buffer is full, then scanning will stop. Scanning will continue when enough space is available for the current label.

When No Buffering is selected then scanning will be stopped until the current label is completely transmitted.

When One Label Buffering is selected the scanner will allow the oper- ator to scan one more label in addition to the label already in the transmit buffer. In other words, one label may be scanned beyond the label being transmitted.

NE

Full Buffering

NF

NG

No Buffering

One Label Buffering

No Read Option

The scanner can be programmed to send a no read message (‘NR’) upon a scan that does not result in a good read.

NX

Enable No Read

NY

Disable No Read *

06656

19

Page 27
Image 27
Datalogic Scanning DS1100 SH2347, DS2200 SH2348 manual No Read Option, Full Buffering No Buffering One Label Buffering