Troubleshooting

Problem

Possible Cause

 

Solution

 

 

 

 

 

 

 

Time-out fault: the

In either case, if the Spare Battery LED is

 

spare battery pack

flashing red, do the following:

 

charging has

1.

Disconnect the AC adapter from the dock.

 

exceeded the maxi-

 

2.

Remove the spare battery pack and the

 

mum time-out period.

 

 

Pegaso from the dock.

 

 

 

 

3.

Connect the AC adapter to the dock.

The Spare Battery

 

4.

If the Spare Battery LED is flashing red,

LED on the dock is

Over-voltage fault: the

there is a problem with the dock. Disconnect

flashing RED.

spare battery pack

the AC adapter from the dock and contact a

 

charging has

service technician.

 

5.

If the Spare Battery LED is off, insert a dif-

 

exceeded the maxi-

 

mum charge voltage

ferent spare battery pack in the dock.

 

of the battery.

6.

Otherwise, there is a problem with the first

 

 

spare battery pack. Discontinue use of the first

 

 

spare battery pack. Refer to the PRG for

 

 

instructions on battery disposal.

 

 

 

 

30

Pegaso™ Industrial PDA with Windows® CE

Page 32
Image 32
Datalogic Scanning Industrial PDA manual Flashing RED