Datalogic Scanning PD7100 manual Flash On Time Setting Examples, ‘0’ and ‘5’

Models: PD7100

1 324
Download 324 pages 40.75 Kb
Page 45
Image 45

Flash On Time

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode. The se- lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in- crements.

Follow these instructions to set this feature.

1.Determine the desired setting in milliseconds.

2.Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode.

4.Scan the barcode: SELECT FLASH ON TIME SETTING.

5.Scan the appropriate two digits from the keypad in Appendix E, Keypad represent- ing the duration which was determined in the steps above. You will hear a two- beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode.

This completes the procedure. See Table 5 for some examples of how to set this feature.

Table 5. Flash On Time Setting Examples

STEP

ACTION

 

EXAMPLES

 

 

 

 

 

 

 

1

Desired Setting

500ms

1,000ms (1 sec.)

5200ms (5.2 sec.)

9,900ms (9.9 sec.)

 

 

 

 

 

 

2

Divide by 100 (and pad with

05

10

52

99

leading zeroes to yield two digits)

 

 

 

 

 

 

 

 

 

 

 

3

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

4

Scan SELECT FLASH OFF TIME SETTING

 

 

 

 

 

 

 

 

 

5

Scan Two Characters From

‘0’ and ‘5’

‘1’ and ‘0’

‘5’ and ‘2’

‘9’ and ‘9’

Appendix E, Keypad

 

 

 

 

 

 

 

 

 

 

 

6

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

Product Reference Guide

37

Page 45
Image 45
Datalogic Scanning PD7100 manual Flash On Time Setting Examples, ‘0’ and ‘5’