Datalogic Scanning PD7100 manual Parity = None Parity = Even Parity = Odd

Models: PD7100

1 324
Download 324 pages 40.75 Kb
Page 59
Image 59

Parity

Parity

This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.

Select None when no parity bit is required.

Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

ENTER/EXIT PROGRAMMING MODE

DEFAULT

Parity = None

Parity = Even

Parity = Odd