Datalogic Scanning PD7100 manual GS1 DataBar Expanded Length 2 Setting Examples

Models: PD7100

1 324
Download 324 pages 40.75 Kb
Page 162
Image 162

Symbologies

GS1 DataBar Expanded — cont.

GS1 DataBar Expanded Set Length 2

This feature specifies one of the barcode lengths for GS1 DataBar Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the sec- ond fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only.

The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length).

Follow these instructions to set this feature:

1.Determine the desired character length (from 1 to 74). Pad the number with lead- ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode.

3.Scan the barcode: SELECT GS1 DATABAR EXPANDED LENGTH 2 SET- TING.

4.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

5.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode.

This completes the procedure. See Table 20 for some examples of how to set this feature.

Table 20. GS1 DataBar Expanded Length 2 Setting Examples

STEP

ACTION

 

EXAMPLES

 

 

 

 

 

 

 

1

Desired Setting

00 (ignore second

07 Characters

52 Characters

74 Characters

length)

 

 

 

 

 

 

 

 

 

 

 

2

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

3

Scan SELECT GS1 DATABAR EXPANDED LENGTH 2 SETTING

 

 

 

 

 

 

 

 

4

Scan Two Characters From

‘0’ and ‘0’

‘0’ and ‘7’

‘5’ and ‘2’

‘7’ and ‘4’

Appendix E, Keypad

 

 

 

 

 

 

 

 

 

 

 

5

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

154

PowerScan® PD7100 Corded

Page 162
Image 162