Datalogic Scanning PD7100 manual Code 32 Enable/Disable, Code 32 Feature Setting Exceptions

Models: PD7100

1 324
Download 324 pages 40.75 Kb
Page 183
Image 183

Code 32

Code 32

The following options apply to the Code 32 (Italian Pharamaceutical Code) symbology.

Code 32 Enable/Disable

When disabled, the reader will not read Code 32 barcodes.

ENTER/EXIT PROGRAMMING MODE

DEFAULT

Code 32 = Disable

Code 32 = Enable

Code 32 Feature Setting Exceptions

The following features are set for Code 32 by using these Code 39 settings:

Code 39 Quiet Zones on page 162

Code 39 Minimum Reads on page 163

NOTE Code 39 Decoding Level on page 164

Code 39 Interdigit Ratio on page 171

Code 39 Character Correlation on page 173

Code 39 Stitching on page 174