INDICATION

DESCRIPTION

LED

BEEPER

 

 

 

 

 

 

 

 

 

The reader is in the process of pow-

 

Reader beeps four times at highest

Power-up Beep

 

frequency and volume upon power-

ering-up.

 

 

 

up.

 

 

 

 

 

 

 

 

 

LED behavior for this indica-

The reader will beep once at current

Good Read Beep

A label has been successfully

tion is configurable via the

frequency, volume, mono/bi-tonal

scanned by the reader.

feature “Good Read: When to

setting and duration upon a suc-

 

 

 

Indicate

cessful label scan.

 

 

 

 

ROM Failure

There is an error in the reader's soft-

Flashes

Reader sounds one error beep at

ware/programming

highest volume.

 

 

 

 

 

 

Limited Scanning

Indicates that a host connection is

 

Reader 'chirps' six times at the

not established when the IBM or

N/A

highest frequency and current vol-

Label Read

USB interface is enabled.

 

ume.

 

 

 

 

 

 

Reader Active

The reader is active and ready to

The LED is lit steadilya

N/A

Mode

scan.

 

 

 

 

 

 

Reader

The reader has been disabled by

The LED blinks continuously

N/A

Disabled

the host.

 

 

 

 

 

 

 

While in Object Sense mode or Trig-

 

 

Green Spot is on

ger Object Sense mode the green

N/A

N/A

continuously

spot shall be on while in stand

 

 

 

watch state.

 

 

 

 

 

 

Green Spota

Upon successful read of a label, the

 

 

software shall turn the green spot on

 

 

flashes momen-

N/A

N/A

for the time specified by the config-

tarily

 

 

ured value.

 

 

 

 

 

 

 

 

 

Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.

 

 

 

 

Label Programming

A valid programming label has been

LED blinks continuously

Reader sounds four low frequency

Mode Entry

scanned.

beeps.

 

 

 

 

 

Label Programming

 

 

Reader sounds three times at low-

Mode Rejection of

A label has been rejected.

N/A

est frequency & current volume.

Label

 

 

 

 

 

 

 

 

 

 

In cases where multiple labels must

 

 

Label Programming

be scanned to program one feature,

 

Reader sounds one short beep at

Mode Acceptance

this indication acknowledges each

N/A

highest frequency & current volume.

of Partial Label

portion as it is successfully

 

 

 

 

scanned.

 

 

 

 

 

 

Label Programming

Configuration option(s) have been

 

Reader sounds one high frequency

successfully programmed via labels

 

Mode Acceptance

N/A

beep and 4 low frequency beeps

and the reader has exited Program-

of Programming

 

followed by reset beeps.

ming Mode.

 

 

 

 

 

 

 

 

Label Programming

 

 

Reader sounds two times at low fre-

Mode Cancel Item

Cancel label has been scanned.

N/A

quency and current volume.

Entry

 

 

 

 

 