LED and Beeper Indications
INDICATION | DESCRIPTION | LED | BEEPER | |
|
|
|
| |
|
|
|
| |
| The reader is in the process of pow- |
| Reader beeps four times at highest | |
| frequency and volume upon power- | |||
| ||||
|
| up. | ||
|
|
| ||
|
|
|
| |
|
| LED behavior for this indica- | The reader will beep once at current | |
Good Read Beep | A label has been successfully | tion is configurable via the | frequency, volume, | |
scanned by the reader. | feature “Good Read: When to | setting and duration upon a suc- | ||
| ||||
|
| Indicate” | cessful label scan. | |
|
|
|
| |
ROM Failure | There is an error in the reader's soft- | Flashes | Reader sounds one error beep at | |
ware/programming | highest volume. | |||
|
| |||
|
|
|
| |
Limited Scanning | Indicates that a host connection is |
| Reader 'chirps' six times at the | |
not established when the IBM or | N/A | highest frequency and current vol- | ||
Label Read | ||||
USB interface is enabled. |
| ume. | ||
|
| |||
|
|
|
| |
Reader Active | The reader is active and ready to | The LED is lit steadilya | N/A | |
Mode | scan. | |||
|
| |||
|
|
|
| |
Reader | The reader has been disabled by | The LED blinks continuously | N/A | |
Disabled | the host. | |||
|
| |||
|
|
|
| |
| While in Object Sense mode or Trig- |
|
| |
Green Spot is on | ger Object Sense mode the green | N/A | N/A | |
continuously | spot shall be on while in stand | |||
|
| |||
| watch state. |
|
| |
|
|
|
| |
Green Spota | Upon successful read of a label, the |
|
| |
software shall turn the green spot on |
|
| ||
flashes momen- | N/A | N/A | ||
for the time specified by the config- | ||||
tarily |
|
| ||
ured value. |
|
| ||
|
|
| ||
|
|
|
| |
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. | ||||
|
|
|
| |
Label Programming | A valid programming label has been | LED blinks continuously | Reader sounds four low frequency | |
Mode Entry | scanned. | beeps. | ||
| ||||
|
|
|
| |
Label Programming |
|
| Reader sounds three times at low- | |
Mode Rejection of | A label has been rejected. | N/A | ||
est frequency & current volume. | ||||
Label |
|
| ||
|
|
| ||
|
|
|
| |
| In cases where multiple labels must |
|
| |
Label Programming | be scanned to program one feature, |
| Reader sounds one short beep at | |
Mode Acceptance | this indication acknowledges each | N/A | ||
highest frequency & current volume. | ||||
of Partial Label | portion as it is successfully |
| ||
|
| |||
| scanned. |
|
| |
|
|
|
| |
Label Programming | Configuration option(s) have been |
| Reader sounds one high frequency | |
successfully programmed via labels |
| |||
Mode Acceptance | N/A | beep and 4 low frequency beeps | ||
and the reader has exited Program- | ||||
of Programming |
| followed by reset beeps. | ||
ming Mode. |
| |||
|
|
| ||
|
|
|
| |
Label Programming |
|
| Reader sounds two times at low fre- | |
Mode Cancel Item | Cancel label has been scanned. | N/A | ||
quency and current volume. | ||||
Entry |
|
| ||
|
|
|
a.Except when in sleep mode or when a Good Read LED Duration other than 00 is selected
288 | PowerScan® PD7100 Corded |