Wedge Quiet Interval

Wedge Quiet Interval

This option specifies the amount of time to look for keyboard activity before the read- er breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments.

This feature applies ONLY to the Keyboard Wedge interface.

NOTE

Follow these instructions to set this feature:

1.Determine the desired setting in milliseconds.

2.Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode.

4.Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING.

5.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode.

This completes the procedure to set the Wedge Quiet Interval. See Table 14 for some examples of how to set this feature.

Table 14. Timeout Setting Examples

STEP

ACTION

 

 

EXAMPLES

 

 

 

 

 

 

 

 

1

Desired Setting

10ms

150ms

 

600ms

850ms

 

 

 

 

 

 

 

2

Divide by 10 (and pad with leading

01

15

 

60

85

zeroes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

 

4

Scan SELECT WEDGE QUIET INTERVAL SETTING

 

 

 

 

 

 

 

 

 

 

 

5

Scan Two Characters From

‘0’ and ‘1’

‘1’ and ‘5’

 

‘6’ and ‘0’

‘8’ and ‘5’

Appendix E, Keypad

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

 

 