Wedge Quiet Interval
Wedge Quiet Interval
This option specifies the amount of time to look for keyboard activity before the read- er breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments.
This feature applies ONLY to the Keyboard Wedge interface.
NOTE
Follow these instructions to set this feature:
1.Determine the desired setting in milliseconds.
2.Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode.
4.Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING.
5.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the duration which was determined in the steps above. You will hear a two- beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode.
This completes the procedure to set the Wedge Quiet Interval. See Table 14 for some examples of how to set this feature.
Table 14. Timeout Setting Examples
STEP | ACTION |
|
| EXAMPLES |
| |
|
|
|
|
|
|
|
1 | Desired Setting | 10ms | 150ms |
| 600ms | 850ms |
|
|
|
|
|
|
|
2 | Divide by 10 (and pad with leading | 01 | 15 |
| 60 | 85 |
zeroes) |
| |||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
3 | Scan ENTER/EXIT PROGRAMMING MODE |
|
|
|
| |
|
|
|
|
|
| |
4 | Scan SELECT WEDGE QUIET INTERVAL SETTING |
|
|
|
| |
|
|
|
|
|
|
|
5 | Scan Two Characters From | ‘0’ and ‘1’ | ‘1’ and ‘5’ |
| ‘6’ and ‘0’ | ‘8’ and ‘5’ |
Appendix E, Keypad |
| |||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
6 | Scan ENTER/EXIT PROGRAMMING MODE |
|
|
|
| |
|
|
|
|
|
|
|
Product Reference Guide | 79 |