Datalogic 2 of 5

Datalogic 2 of 5 — cont.

Datalogic 2 of 5 Set Length 2

This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s check and data char- acters.

The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).

Follow these instructions to set this feature:

1.Determine the desired character length (from 2 to 50, or 0 to ignore this length). The length must be an even number.

2.Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode.

4.Scan the barcode: SELECT Datalogic 2 of 5 LENGTH 2 SETTING.

5.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that rep- resent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode.

This completes the procedure. See Table 28 for some examples of how to set this feature.

Table 28. Datalogic 2 of 5 Length 2 Setting Examples

STEP

ACTION

 

 

 

EXAMPLES

 

 

 

 

 

 

 

 

1

Desired Setting

Ignore This Length

 

4 Characters

 

14 Characters

50 Characters

 

 

 

 

 

 

 

 

2

Pad with leading zeroes to yield

00

 

04

 

14

50

two digits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

 

4

Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING

 

 

 

 

 

 

 

 

 

 

 

 

5

Scan Two Characters From

‘0’ and ‘0’

 

‘0’ and ‘4’

 

‘1’ and ‘4’

‘5’ AND ‘0’

Appendix E, Keypad

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Scan ENTER/EXIT PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

 

 

 

Product Reference Guide

211

Page 219
Image 219
Datalogic Scanning PD7100 manual Datalogic 2 of 5 Length 2 Setting Examples