2

SC6000

2.4 ELECTRICAL CONNECTIONS

The connectors available for each scanner model are the following:

Scanner Model

Connector

Type

 

 

Power/Net

25-pin male power supply, lonworks and

 

 

 

input/output signals

 

 

Extended I/O

25-pin female extended I/O signals (optoisolated)

 

All models

Modem

9-pin male modem connection

 

 

Main

9-pin female RS232/RS485 main serial connection

 

 

Aux

9-pin female RS232 auxiliary connection

 

 

Eth-1

RJ45 modular Ethernet network

-

1230

Eth-2

RJ45 modular Ethernet network

-

1211

Profibus

9-pin female Profibus network

-

1215

DeviceNet

5-pin male DeviceNet network

2.4.1Auxiliary Interface

The auxiliary serial interface is equipped with RS232 interface connections. The interface can be enabled or disabled through the Genius™ configuration program.

The following pins of the 9-pin connector are used for RS232 interface connection:

9-pin D-sub Female Connector Pinout

Pin

Name

Function

5

1

 

 

2

TX

Transmit

 

 

3

RX

Receive

9

6

5

GND

Ground

9-pin D-sub Female Connector

SC6000

USER INTERFACE (Laptop)

3

RXAUX

 

TXD

2

TXAUX

5

RXD

GND

 

Signal Ground

Shield

 

Figure 14 - RS232 Auxiliary Interface Connections

8