SOFTWARE CONFIGURATION
3
3.4 PARAMETER DEFAULT VALUES
The following table contains the list of the factory default settings for the SC6000 Controller. Genius™ also allows checking the parameter default values by selecting the "Compare parameters" option available in the Tools menu and comparing the current SC6000 configuration to the default one.
Parameter | Default Setting |
|
|
Code Definition |
|
Code Combination | Single Label |
No Read Message | Global No Read Message |
No Read String (128 characters max) | <CAN> |
Code Label Settings#1 |
|
Enable | Enabled (checked) |
Code Symbology | Interleaved 2 of 5 |
Label Length | 8 |
Min Code Position | 0 |
Max Code Position | 255 |
CheckDigit | Disabled (unchecked) |
Pattern Match String (200 char. max) | NULL |
Code Label Settings#2 |
|
Enable | Enabled (checked) |
Code Symbology | Code39 |
Label Length | Variable |
Minimum Label Length | 1 |
Maximum Label Length | 60 |
Min Code Position | 0 |
Max Code Position | 255 |
CheckDigit | Disabled (unchecked) |
Pattern Match String (200 char. max.) | NULL |
Code Label Settings#3 |
|
Enable | Disabled (unchecked) |
Code Label Settings#4 |
|
Enable | Disabled (unchecked) |
Code Label Settings#5 |
|
Enable | Disabled (unchecked) |
Code Label Settings#6 |
|
Enable | Disabled (unchecked) |
Code Label Settings#7 |
|
Enable | Disabled (unchecked) |
Code Label Settings#8 |
|
Enable | Disabled (unchecked) |
Code Label Settings#9 |
|
Enable | Disabled (unchecked) |
Code Label Settings#10 |
|
Enable | Disabled (unchecked) |