2

SC6000

Reading Performance Window

This window displays the following data:

Number of the processed parcels

Good Read Rate

No Read Rate

Multiple Read Rate

Reading Mask Window

This window indicates the node that performed a reading of the codes enabled on the master.

The following indicators are used:

"* " The node read a barcode enabled on the master.

"- " The node read no barcode.

I/O Status Window

This window provides data concerning the conveyor speed and the digital input/output status.

System Info Window

This window provides information about the software release.

2.6.2Menu Mode

For security purposes, the menu mode is entered by pressing the ENTER and MENU keys at the same time.

Through this menu, it is possible to perform the following:

Main Parameter Setting: IP address, Netmask, Gateway address; Profibus address (for Profibus models); DeviceNet address (for DeviceNet models); supplementary IP address, supplementary Netmask, and supplementary Gateway address (for Dual Ethernet models).

These parameters may be set through the Genius™ program (see chapter 3 for details).

Date&Time setting;

DARP™ (Datalogic Automatic Replacement Procedure);

CASP™ (Cluster AutoSetup Procedure): this procedure allows automatic address assignment to the scanner cluster nodes. This operation can also be performed by starting up the system while pressing the SETUP key.

16