MAINTENANCE
4
4 MAINTENANCE
4.1 DATALOGIC AUTOMATIC REPLACEMENT PROCEDURE (DARPTM)
Once the system configuration has been completed, launch the DARP™ backup by one of the following methods:
Using Genius:
Click on the DARP™ backup icon in the Device Network area. You will be prompted to select the desired backup option (complete, all scanners, controller, or each single scanner).
Using the SC6000 keypad:
1.Press the <Ent> and <Menu> keys simultaneously to enter the Menu;
2.Use the <arrow> keys to move within the menu items;
3.In the <System> menu choose <Backup> and select the desired backup option (complete, all scanners, controller, or each single scanner).
The SC6000 Controller will store the complete system configuration on the Compact Flash card.
If a slave scanner has to be replaced, the corresponding configuration (node address, code configuration, PackTrack™ configuration, etc.) is automatically downloaded by the SC6000 into the new scanner at the next system startup.
Systems with DS8100 or DX8200 slave scanners must have been installed according to the procedure in par. 3.3.
NOTE
In case of SC6000 failure, the complete system configuration can be recovered from the damaged SC6000 Compact Flash: by simply installing the old Compact Flash in the new SC6000, the system configuration is automatically restored and the reading station is ready to start working again.
Before removing the Compact Flash card, switch the SC6000 Controller off.
CAUTION
31