TROUBLESHOOTING
5
5 TROUBLESHOOTING
Before contacting your local Datalogic office or Datalogic Partner or ARC, it is suggested to save the device configuration to a *.ddc file by means of the Genius™ software configuration program and check the exact device model and serial number.
NOTE
TROUBLESHOOTING GUIDE| Problem | Suggestion | 
 | 
 | 
 | 
 | ||
| Power On: | • | Is power connected? | 
 | 
 | |||
| the “Power On” LED is not lit. | • If using a power adapter, is it connected to | ||||||
| 
 | 
 | PWO  | 
 | 
 | 
 | ||
| On Line Mode 1: | • Check carefully if | you are referring to the | |||||
| the "PS” LED is not lit (when external | 
 | 
 | 
 | ||||
| trigger activates). | • Is sensor connected to PWO PS input? | 
 | |||||
| 
 | • Is power supplied to photo sensor? | 
 | |||||
| On Line Mode 1: | • Is the software configuration consistent with | ||||||
| the "PS” LED is correctly lit but nothing | 
 | the application condition (operating mode, | |||||
| happens (no reading results). | 
 | etc.)? | 
 | 
 | 
 | 
 | |
| 
 | 
 | In the Genius™ software configuration | |||||
| 
 | 
 | program select the OPERATING MODES | |||||
| 
 | 
 | folder and check for related parameters. | 
 | ||||
| Serial On Line Mode: | • In | the | Genius™ | program | select | the | |
| the reader is not triggered (no reading | 
 | OPERATING MODE folder and check if | |||||
| results). | 
 | serial on line is enabled as “On Line options” | |||||
| 
 | 
 | parameter value. | 
 | 
 | 
 | ||
| 
 | • Are the  | ||||||
| 
 | • | Is the serial trigger source correctly | |||||
| 
 | 
 | connected and configured)? | 
 | 
 | |||
| On Line Mode and Serial On Line | • In | the | Genius™ | software | configuration | ||
| Mode: | 
 | program select the OPERATING MODES | |||||
| the reader does not respond correctly to | 
 | folder and check the “Reading Phase | |||||
| the expected external signal end. | 
 | Timeout” parameterization. | 
 | 
 | |||
| Communication (Main / Aux): | • Is serial Main / Aux cable connected? | 
 | |||||
| the device is not transmitting anything to | • | Is wiring correct? | 
 | 
 | 
 | ||
| the host. | • If using the Main RS232 or RS485 interface, | ||||||
| 
 | 
 | is | the | reference | ground connected | to | |
| 
 | 
 | GND_ISO? Be careful that it is not | |||||
| 
 | 
 | completely different from GND power ground. | |||||
| 
 | • Are | serial host settings equivalent to serial | |||||
| 
 | 
 | device setting? | 
 | 
 | 
 | ||
| 
 | • When using the Main interface, Tx Data and | ||||||
| 
 | 
 | Rx Data LEDs must be lit during data | |||||
| 
 | 
 | transfer. | 
 | 
 | 
 | 
 | |