A
SC6000
SC6000 | PWO | USER INTERFACE |
| VS_INPUTS | V |
| A/B | Signal |
| B/A | Ground |
|
| |
| GND |
|
Figure 44 - PNP Command Input Using System Power
SC6000 | PWO | USER INTERFACE |
| VS_INPUTS | V |
| A/B |
|
| B/A |
|
| GND | Signal |
|
| Ground |
Figure 45 - NPN Command Input Using System Power
Isolation between the command logic and the scanner is maintained by powering the inputs with an external supply voltage (Vext). For convenience, the inputs can be powered using the VS_INPUTS signal on the SC6000 (pin 9). In this case, however, the device is no longer electrically isolated. The VS_INPUTS signal on the Extended I/O connector is
The electrical features of these inputs are:
Maximum voltage 30 V Maximum current 10 mA
Outputs
Six general purpose outputs are available.
Pin | Name | Function |
|
6 | OUT 1+ | Configurable digital output 1 – positive pin | |
19 | OUT 1- | Configurable digital output 1 – negative pin | |
7 | OUT 2+ | Configurable digital output 2 – positive pin | |
20 | OUT 2- | Configurable digital output 2 – negative pin | |
8 | OUT 3+ | Configurable digital output 3 – positive pin | |
21 | OUT 3- | Configurable digital output 3 – negative pin | |
10 | OUT 4+ | Configurable digital output 4 – positive pin | |
23 | OUT 4- | Configurable digital output 4 – negative pin | |
11 | OUT 5+ | Configurable digital output 5 – positive pin | |
24 | OUT 5- | Configurable digital output 5 | – negative pin |
12 | OUT 6+ | Configurable digital output 6 | – positive pin |
25 | OUT 6- | Configurable digital output 6 | – negative pin |
The function of all six outputs can be defined by the user.
Refer to Genius™ Help
42