A

SC6000

SC6000

PWO

USER INTERFACE

 

VS_INPUTS

V

 

A/B

Signal

 

B/A

Ground

 

 

 

GND

 

Figure 44 - PNP Command Input Using System Power

SC6000

PWO

USER INTERFACE

 

VS_INPUTS

V

 

A/B

 

 

B/A

 

 

GND

Signal

 

 

Ground

Figure 45 - NPN Command Input Using System Power

Isolation between the command logic and the scanner is maintained by powering the inputs with an external supply voltage (Vext). For convenience, the inputs can be powered using the VS_INPUTS signal on the SC6000 (pin 9). In this case, however, the device is no longer electrically isolated. The VS_INPUTS signal on the Extended I/O connector is short-circuit protected.

The electrical features of these inputs are:

Maximum voltage 30 V Maximum current 10 mA

Outputs

Six general purpose outputs are available.

Pin

Name

Function

 

6

OUT 1+

Configurable digital output 1 – positive pin

19

OUT 1-

Configurable digital output 1 – negative pin

7

OUT 2+

Configurable digital output 2 – positive pin

20

OUT 2-

Configurable digital output 2 – negative pin

8

OUT 3+

Configurable digital output 3 – positive pin

21

OUT 3-

Configurable digital output 3 – negative pin

10

OUT 4+

Configurable digital output 4 – positive pin

23

OUT 4-

Configurable digital output 4 – negative pin

11

OUT 5+

Configurable digital output 5 – positive pin

24

OUT 5-

Configurable digital output 5

– negative pin

12

OUT 6+

Configurable digital output 6

– positive pin

25

OUT 6-

Configurable digital output 6

– negative pin

The function of all six outputs can be defined by the user.

Refer to Genius™ Help On-Line for further details.