SOFTWARE CONFIGURATION

3

3.2.2Alternative Slave Address Assignment

As alternatives to Network Setup through the Master, each Slave scanner can be assigned an address through the following methods:

random address assignment from SC6000 to all slaves in the network by performing the CASP™ procedure as described in par. 2.6.2;

address setting through the Local Device Network Settings item in the Device Menu with the slave scanner connected to Genius™;

manual address setting through slave scanner keyboard (see par. “Internal Net” in the relative Scanner Reference Manual for details);

3.3GUIDE TO RAPID CONFIGURATION FOR DS8100 AND DX8200 SLAVE SCANNERS

1)Connect to each scanner Debug port and set a Lonworks Node address which must be different and consecutive (i.e. 1, 2, 3, 4, etc.).

2)Make all the necessary PackTrack parameter settings.

3)Run Genius™ from the configuration PC. The following window appears asking to select the configuration mode.

Figure 29 - Genius™ Wizard Opening Window

Select Advanced. The Wizard option is not currently available for SC6000.

23