SOFTWARE CONFIGURATION

3

Each device is indicated by the following graphical objects:

check box allowing to select/deselect a specific device to perform the desired operations (i.e. program downloading);

icon representing the device status;

a label reporting information transmitted by the device when connected (the device address, generated errors, device description).

4.Then, proceed with the Network Setup (par. 3.2.1).

5.Configure the SC6000 and Slave Scanner parameters according to your application using the configuration window in Genius™ for each device. The main steps are:

Configure the PackTrack parameters

Select the codes to be read

Set-up the communication parameters

Define data formatting parameters

6.Send the configuration to the Slave Scanners from the Send command in the Device Menu.

7.Perform a DARP™ backup by clicking the relative icon in the Device Network area.

3.2.1Genius™ Network Setup Through Master

Network Setup allows configuring your Local Lonworks Network through the Master using Genius™.

Three different procedures are available to define the number of network slave scanners, their label and address according to two main conditions:

Condition

Available Procedure

Feature

Unknown Slave Addresses

Net-Autoset

automatically assigns random addresses to

 

 

slave or Stand Alone scanners.

Known Slave Addresses

Network Wizard

customizes the network (slave label and

 

 

address definition and physical identification

 

 

of a specific slave within network), updates

 

 

configuration to a file and makes it ready to

 

 

be sent to the Master.

 

Express Network Setup

automatically performs all the operations of

 

 

the Network Wizard apart from the physical

 

 

identification of a specific slave scanner.

The Network Setup procedure as described requires Genius™ software version 1.06 or later. In addition, the Net-Autoset procedure requires scanner software version 6.40 or later.

NOTE

19