17) INTERNAL MODULE

18) LABEL ALIGNMENT (see section

Sets the number of 4K Byte blocks

4.5 for more information)

Sets Label Alignment Method.

allocated for the internal RAM

module.

Possible Values:

 

Possible Values:

YES

(printer uses ‘ALIGNMENT

 

0 – 255; default = *128

AUTO

LENGTH’ or host sent value)

 

(printer will automatically

 

 

determine label length)

 

* NO

(Label Alignment disabled)

 

 

19) ALIGNMENT LENGTH (see

20) STOP LOCATION

section 4.5 for more information)

Sets convenient stop locations for

Leading edge to leading edge

different printer configurations.

distance of two successive labels.

Possible Values:

Must be set when ‘LABEL

ALIGNMENT’ is set to Yes.

*HOST

(printer uses host values of SOP

 

Possible Values:

 

and Present Distance)

PEEL

(sets stop location just behind the

 

0 – 999; default =100*

 

peel bar)

Units: .01 inch

CUT

(sets stop location at the cutter

 

 

blade)

 

COVER (sets stop location at the tear plate)

 

NONE

(printer uses normal start location

 

 

and ignores host commands)

*= Default Setting

All of the menu items listed in the previous tables are stored in non-volatile memory.